/ Perfect Charging / Perfect Welding / Solar Energy
42,0426,0093,EN 018-29122014
Acctiva Professional 35 A
Acctiva Professional 35 A UCN
Operating Instructions
Battery charging system
EN
Seitenansicht 0
1 2 3 4 5 6 ... 47 48

Inhaltsverzeichnis

Seite 1 - Acctiva Professional 35 A UCN

/ Perfect Charging / Perfect Welding / Solar Energy42,0426,0093,EN 018-29122014Acctiva Professional 35 AAcctiva Professional 35 A UCNOperating Instruc

Seite 2

8Safety measures in normal opera-tionEMC Device Clas-sificationsEMC measuresData protection- Chargers with a ground conductor must only be operated on

Seite 3 - Dear reader

9ENMaintenance and repairWarranty and lia-bilitySafety inspectionSafety symbolsUnder normal operating conditions, the device requires only a minimum o

Seite 4

10DisposalCopyrightDevices displaying this TÜV test mark satisfy the requirements of the relevant standards in Japan.Devices displaying this TÜV test

Seite 5 - Contents

11ENSafety rules - required for USA, Canada and Austral-iaGeneral and elec-trical risksKEEP THESE INSTRUCTIONS CAREFULLY - This guide contains importa

Seite 6

12If skin or clothing comes into contact with battery acid, wash the acid immediately with soap and water. If acid gets into the eye, rinse the eye im

Seite 7 - Safety rules

13ENSteps to follow with battery in-stalled in vehicleFollow these steps if the battery is installed in the vehicle. A spark near to the battery can c

Seite 8 - *)

14This device is designed for more than 15 amperes and must be operated on a circuit with a nominal voltage of 120 volts. The device is equipped in th

Seite 9

15ENGeneral informationPrinciple The main feature of the new Active Inverter Technology is intelligent charging. This means that the charging behaviou

Seite 10

16Start-upSafetyProper use The charger is designed to charge the batteries listed below. Any other use or use beyond this purpose is deemed improper.

Seite 11

17ENControl elements and connectionsGeneral remarksControl panelNo. Function(1) Graphic display(2) Menu key- Select the desired setting, e.g. Ah(3) Up

Seite 13

18ConnectionsNo. Function(1) Mains cable safety clip(2) AC input - mains socket(3) Connection P2 - I/O port - no function, can be retrofitted howeverf

Seite 14

19ENRemoving covers for connections and optionsIf necessary, use a screwdriver to remove:- Cover (1) for connection P3 - visual port- Cover (2) for co

Seite 15

20Wall bracket op-tionPreparations for security lockThe security lock is not contained in the scope of supply.A security lock can only be attached - t

Seite 16

21ENSpace requirements with edge guardSpace requirements without edge guard, and space requirements with signal lamp and bracket options (* space for

Seite 17 - General information

22Operating modesGeneral informa-tionThe charger is suitable for all 6/12/24 V lead acid batteries (wet, MF, AGM and GEL).Available operat-ing modesTh

Seite 18 - Start-up

23ENRefresh modeRefresh mode reactivates deeply dischar-ged or sulphated batteries. Refresh char-ging of batteries must be carried out either in the o

Seite 19 - (2)(1) (3) (4)

24Charging modeGeneral informa-tionCharging mode is used for:- Charging or conservation charging with the battery either fitted or removed- Charging w

Seite 20

25ENIf the battery voltage selection window does not open, then the battery is in a state of ex-treme deep-discharge (less than 2 V). In this case, it

Seite 21 - (1) (2) (3) (4)

26Restarting charg-ingPress the Stop/Start button to continue charging1

Seite 22 - "click"

27ENBuffering (Trickle) modeGeneral informa-tionBuffering (Trickle) mode is intended exclusively for relieving the battery during a vehicle diagnosis

Seite 23

1ENDear reader,Introduction Thank you for the trust you have placed in our company and congratulations on buying this high-quality Fronius product. Th

Seite 24 - Operating modes

28Disconnect the charger- Disconnect the black charger lead from the negative pole (-) on the battery- Disconnect the red charger lead from the positi

Seite 25

29ENRefresh modeGeneral informa-tionRefresh mode is used to charge the battery if it is suspected that the battery has been in a state of deep-dischar

Seite 26 - Charging mode

30Connect battery - the de-energised charger leads mean there are no sparks when connecting to the battery, even if the charger is already connected t

Seite 27

31ENDuring the analysis phase, the charger mo-nitors the battery voltage and the result is used in the subsequent charging process.- A set of four bar

Seite 28 - Restarting charg

32Battery changing modeGeneral informa-tionBattery changing mode supplies the vehicle electronics with power while the battery is re-placed. Before di

Seite 29 - Buffering (Trickle) mode

33ENIf the battery is in a state of extreme deep-discharge (under 2 V), a warning appears in-structing the user to disconnect the battery.Batteries in

Seite 30

34Power supply modeRequirements In Power supply mode, the charger leads are connected directly to the battery leads or the vehicle jump start points.

Seite 31 - Refresh mode

35ENDevice optionsGeneral informa-tionThe device options allow the following to be configured:- LanguageSelection of language for user guide- Graphic

Seite 32

36- Boost (on/off), factory setting: onBoost on: shorter charging time resulting in the battery being fully charged sooner. The full 35 A of power ava

Seite 33

37ENSynergic linesSafetyAvailable charac-teristicsCharging characteristic IUoU:I1 = Main charging current U1 = Final charging voltage U2 = Conservatio

Seite 35

38Refresh characteristic IUIoU:I1 = Main charging current U1 = Final charging voltage I2 = Recharging current U2 = Conservation charging voltageI1U1U2

Seite 36 - Power supply mode

39ENTroubleshootingSafetyProtective equip-mentCharger leads connected to wrong poles, reverse polarity protection has trippedRemedy:- Connect battery

Seite 37 - Device options

40Charging errorsNo. 30: Timeout in the corresponding char-ging phaseRemedy:- Set Ah to correct value- Check for parallel consumers (car ra-dio, etc.)

Seite 38

41ENNo. 50: Device output fuse defectiveRemedy:- Contact After-Sales ServiceNo. 51: Secondary temperature out of rangeRemedy:- Contact After-Sales Ser

Seite 39 - Synergic lines

42Technical dataElectrical data in-put 230VStandards 230VElectrical data in-put 120 VStandards 120VMains voltage ~ 230 V AC, +/- 15 %Mains frequency

Seite 40

43ENElectrical data outputBattery dataTechnical dataEnvironmental conditionsIEC 60068-2-6 Sinusoidal vibration (sine 10-55 Hz; 20 cycles / axis; accel

Seite 43

Fronius Worldwide - www.fronius.com/addressesUnder http://www.fronius.com/addresses you will find all addresses of our sales branches and partner firm

Seite 44 - Technical data

3ENContentsSafety rules ...

Seite 45

4Power Supply mode... 23Dev

Seite 46

5ENSafety rulesExplanation of safety symbolsIf you see any of the symbols depicted in the "Safety rules" chapter, special care is re-quired.

Seite 47

6Proper useEnvironmental conditionsMains connectionDangers from mains current and charging cur-rentThe device is to be used exclusively for its intend

Seite 48

7ENDangers from ac-id, gases and va-poursGeneral informa-tion regarding the handling of bat-teriesProtecting your-self and othersBatteries contain aci